        CLIMAVENETA

        Products PRODUCT
        ? Location:Home>Products> SC Series - Single Coil Chilled Water
        SC Series - Single Coil Chilled Water
        SC Series - Single Coil Chilled Water

        http://35145.newnetwebnt01.eastftp.net/Site/Default/Uploads/image/20171015/捕獲1.JPGhttp://35145.newnetwebnt01.eastftp.net/Site/Default/Uploads/image/20171015/捕獲3.JPGhttp://35145.newnetwebnt01.eastftp.net/Site/Default/Uploads/image/20171015/捕獲5.JPG

        Coolblade chilled water SCU/O series Cooling capacity: 9kW-220kW The Climaveneta chilled water single-coil computer room air conditioner uses the cold source of the outdoor chilled water host for cooling. The whole series is equipped with standard high-efficiency and low-noise EC fans, CAREL's new generation controller, and electric proportional chilled water regulating valve. The unit has the best cooling performance. The evaporator of the unit adopts a large-area flat plate design, which has the characteristics of low flow resistance and high heat exchange efficiency. The whole system also supports the solution of sunken fan air supply, which can completely sink the fan under the floor.

        Extended Functions:

        Frame Structure Description:

        The overall frame and bottom plate of the unit are made of galvanized steel sheet whose outer surface has been electrostatically sprayed, so that the unit as a whole should not rust. The group structure is reasonable and compact, occupies a small area of the computer room, saves space, and the unit supports full frontal maintenance. In the electric control box of the unit, the strong current and weak current are separated, and the high-power components such as electric heater and humidifier are equipped with independent breakers, and the wiring is standardized, which conforms to the corresponding installation regulations.

        Compressor Description:

        Evaporator Description:

        Condenser:

        Control Cabinet:

        The original components of the control cabinet are all internationally renowned suppliers, and the main control board is the Italian Carle brand. The main components of the air conditioner such as electric heating, humidification, fan, etc. have independent circuit breakers, which is convenient for engineers to maintain and debug the equipment. The control cabinet is also equipped with an emergency main load break switch, which can be conveniently used in emergency or special situations.

        Control System:

        The new generation controller of CAREL is adopted, which supports a variety of control strategies to meet different control requirements. 2. The main control strategy can be changed on site: the unit is controlled by the outlet air temperature or the unit is controlled by the return air temperature. 3. Control strategy of variable air volume: When the indoor load of thecomputer room is reduced, the unit will automatically link the control of the valve and the fan, so that the fan can work under partial load as much as possible to fully achieve the effect of energy saving. 4. Support other control strategies such as: constant air pressure, constant air volume control strategy; air valve linkage control strategy; setting water flow regulating valve opening interval, etc.

        Certification and Honor:

        ISO14001???? ISO9001????ISO18001???? ?CRAA

        Electric Control:

        Chilled water coil:

        The chilled water coil is designed with a large flat plate, and the fins of the heat exchanger are treated with hydrophilic treatment, which can effectively improve the heat exchange efficiency. The pressure bearing capacity of the chilled water coil is greater than or equal to 16kg, effectively eliminating the hidden danger of leakage.

        Fan box:

        The height of the fan box can be defined according to the height of the floor on site, and there is no need to make another bracket on site. A fan baffle is arranged in the fan box to block the turbulence between the fan and the fan. The pipe inlet method of the fan box can be defined by the user, which makes the on-site installation the most convenient.


        EC fan:

        Using zihl-abegg and EBM's new generation of ultra-light EC fans, the impeller material is ultra-light polymer, which makes the operation noise of the computer room AC lower, and the energy saving rate is more than 10%. Inverter fans are not only better than AC fans in terms of energy saving and noise, but also better meet the requirements of today's data centers in terms of control strategies. The computer room air conditioner allows users to remotely read the fan speed, and combined with the upper air pressure sensor, it can also realize advanced functions such as constant air pressure control.

        Cooling Capacity 9KW-220KW
        Refrigerant water/glycol
        Power Input 220V/1N/50或380V/3N/50Hz
        Beijing Huitianyun Project

        Beijing Huitianyun Project

        Area:Beijing
        Cooling Capacity:58980kW
        Period:2016
        Heating Capacity:
        Building Function:Data Center
        System:
        Installed Units:
        194 x SCU100 36 x SCU025 191 x SCU140
        State Grid Corporation Beijing Disaster Recovery Center

        State Grid Corporation Beijing Disaster Recovery Center

        Area:Beijing
        Cooling Capacity:11040kW
        Period:2014
        Heating Capacity:
        Building Function:Data Center
        System:
        Installed Units:
        12 x SCU120 48 x SCU200
        Beijing Sinnet Technology Co., Ltd.

        Beijing Sinnet Technology Co., Ltd.

        Area:Shanghai
        Cooling Capacity:12710kW
        Period:2015
        Heating Capacity:
        Building Function:Data Center
        System:
        Installed Units:
        82 x SCU155B
        China Unicom National Data Center Beijing Yizhuang IDC room

        China Unicom National Data Center Beijing Yizhuang IDC room

        Area:Beijing
        Cooling Capacity:2120kW
        Period:2012
        Heating Capacity:
        Building Function:Data Center
        System:
        Installed Units:
        23×DWU080F 23×BDC103 3×DWU060F 3×BDC078 2×DWU050F 2×BDC062
        BEIJING SINNET TECHNOLOGY CO., LTD.  (2015)

        BEIJING SINNET TECHNOLOGY CO., LTD. (2015)

        Area:Beijing
        Cooling Capacity:7248kW
        Period:2015
        Heating Capacity:
        Building Function:Data Center
        System:
        Installed Units:
        48×SCU100 12×SCU160
        Learn More > >

        Products

        PRODUCT
        SC Series - Single Coil Chilled Water
        SC Series - Single Coil Chilled Water Chilled water single-coil HPAC

        http://35145.newnetwebnt01.eastftp.net/Site/Default/Uploads/image/20171015/捕獲1.JPGhttp://35145.newnetwebnt01.eastftp.net/Site/Default/Uploads/image/20171015/捕獲3.JPGhttp://35145.newnetwebnt01.eastftp.net/Site/Default/Uploads/image/20171015/捕獲5.JPG

        Coolblade chilled water SCU/O series Cooling capacity: 9kW-220kW The Climaveneta chilled water single-coil computer room air conditioner uses the cold source of the outdoor chilled water host for cooling. The whole series is equipped with standard high-efficiency and low-noise EC fans, CAREL's new generation controller, and electric proportional chilled water regulating valve. The unit has the best cooling performance. The evaporator of the unit adopts a large-area flat plate design, which has the characteristics of low flow resistance and high heat exchange efficiency. The whole system also supports the solution of sunken fan air supply, which can completely sink the fan under the floor.
        特點
        CLIMAVENETA
        • Features
        • Technical Data
        • Projects
        • Download
        • Other

        Extended Functions:

        Frame Structure Description:

        The overall frame and bottom plate of the unit are made of galvanized steel sheet whose outer surface has been electrostatically sprayed, so that the unit as a whole should not rust. The group structure is reasonable and compact, occupies a small area of the computer room, saves space, and the unit supports full frontal maintenance. In the electric control box of the unit, the strong current and weak current are separated, and the high-power components such as electric heater and humidifier are equipped with independent breakers, and the wiring is standardized, which conforms to the corresponding installation regulations.

        Compressor Description:

        Evaporator Description:

        Condenser:

        Control Cabinet:

        The original components of the control cabinet are all internationally renowned suppliers, and the main control board is the Italian Carle brand. The main components of the air conditioner such as electric heating, humidification, fan, etc. have independent circuit breakers, which is convenient for engineers to maintain and debug the equipment. The control cabinet is also equipped with an emergency main load break switch, which can be conveniently used in emergency or special situations.

        Control System:

        The new generation controller of CAREL is adopted, which supports a variety of control strategies to meet different control requirements. 2. The main control strategy can be changed on site: the unit is controlled by the outlet air temperature or the unit is controlled by the return air temperature. 3. Control strategy of variable air volume: When the indoor load of thecomputer room is reduced, the unit will automatically link the control of the valve and the fan, so that the fan can work under partial load as much as possible to fully achieve the effect of energy saving. 4. Support other control strategies such as: constant air pressure, constant air volume control strategy; air valve linkage control strategy; setting water flow regulating valve opening interval, etc.

        Certification and Honor:

        ISO14001???? ISO9001????ISO18001???? ?CRAA

        Electric Control:

        Chilled water coil:

        The chilled water coil is designed with a large flat plate, and the fins of the heat exchanger are treated with hydrophilic treatment, which can effectively improve the heat exchange efficiency. The pressure bearing capacity of the chilled water coil is greater than or equal to 16kg, effectively eliminating the hidden danger of leakage.

        Fan box:

        The height of the fan box can be defined according to the height of the floor on site, and there is no need to make another bracket on site. A fan baffle is arranged in the fan box to block the turbulence between the fan and the fan. The pipe inlet method of the fan box can be defined by the user, which makes the on-site installation the most convenient.


        EC fan:

        Using zihl-abegg and EBM's new generation of ultra-light EC fans, the impeller material is ultra-light polymer, which makes the operation noise of the computer room AC lower, and the energy saving rate is more than 10%. Inverter fans are not only better than AC fans in terms of energy saving and noise, but also better meet the requirements of today's data centers in terms of control strategies. The computer room air conditioner allows users to remotely read the fan speed, and combined with the upper air pressure sensor, it can also realize advanced functions such as constant air pressure control.

        Cooling Capacity 9KW-220KW
        Refrigerant water/glycol
        Power Input 220V/1N/50或380V/3N/50Hz
        Changji Yanyue Bay

        Changji Yanyue Bay

        Area:Henan Period:2018 Building Function:Residential buildings System: Cooling Capacity:11111.5kW Heating Capacity:14642.7kW
        Installed Units:

        1 x PSRHH4802-Y-R 1 x PSRHH4502-Y-R 1 x PSRHH5103 1 x PSRHH5003.C-Y 1 x PSRHH9004.C-Y 3x PSRHH2401M

        Qianshan Old Village

        Qianshan Old Village

        Area:Guangdong Period:2014 Building Function:Residential buildings System: Cooling Capacity:22950kW Heating Capacity:7080kW
        Installed Units:

        1 x FOCSWATER4102 3 x FOCSWATER6004C 3 x KMC800LH 3 x PSRHH6003C-R-Y

        Zhengzhou Olympic Sports Center

        Zhengzhou Olympic Sports Center

        Area:Henan? Period:2018 Building Function:Sport structures System: Cooling Capacity:15509kw Heating Capacity:
        Installed Units:

        1 x KMC-1100LY-INV 1 x KMC1100LY 2 x KMC-1100LY-D 1 x CCS0500-INV 2 x CCS0500-INV 2 x FOCSWATER2501

        Five Pine Ice Sports Center

        Five Pine Ice Sports Center

        Area:Beijing? Period:2019 Building Function:Sport structures System: Cooling Capacity:4600kW Heating Capacity:
        Installed Units:

        3 x TECS-W4503L-E

        ?State Grid Chongqing Zhiwang Science and Technology Comprehensive Office Building?

        ?State Grid Chongqing Zhiwang Science and Technology Comprehensive Office Building?

        Area:Chongqing? Period:2021 Building Function:Office Buildings System: Cooling Capacity:4800kW Heating Capacity:5000kW
        Installed Units:

        2 x ERACS3622E-N-D-B 1 x ERACS3602E-N-B 2 x ERACS3622E-N-B 52 x MFC 900 x FCU